Determination of some trace heavy metals in some water samples by FAAS after their preconcentration using DETA

dc.authoridsenkal, bahire filiz/0000-0002-1616-6828
dc.authoridBakircioglu Kurtulus, Yasemin/0000-0003-3013-5793
dc.authoridAkman, Suleyman/0000-0002-8625-783X
dc.authorwosidsenkal, bahire filiz/N-1850-2014
dc.authorwosidBakircioglu Kurtulus, Yasemin/Q-2570-2017
dc.authorwosidAkman, Suleyman/C-1418-2014
dc.contributor.authorBakircioglu, Y
dc.contributor.authorAkman, S
dc.contributor.authorBiçak, N
dc.contributor.authorSenkal, F
dc.date.accessioned2024-06-12T10:59:37Z
dc.date.available2024-06-12T10:59:37Z
dc.date.issued2003
dc.departmentTrakya Üniversitesien_US
dc.description.abstractDiethylenetriamine, DETA polymer was used as a preconcentration of cobalt, iron and nickel prior to their determination by flame atomic. ab-sorption spectrometry (FAAS). Both batch-and column methods were used for the separation and concentration of above metals. These metals were quantitatively retained on the proposed adsorbent at pH 21 then were quantitatively eluted with 2 M hydrochloric acid or nitric acid. The recoveries of metal ions were greater than 98%. Detection limits (3 delta) were 1.5 g/L for Co, 2 . I g/L for Fe and 1.9 g/L for Ni. The relative standard deviations for the determinations were found to be 1.0-8.8%. The effect of Na on the preconcentration of trace metals has also been investigated. The method was applied to tap, ground and lake water samples.en_US
dc.identifier.doi10.1081/TMA-120020259
dc.identifier.endpage248en_US
dc.identifier.issn0733-4680
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-0038205880en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage239en_US
dc.identifier.urihttps://doi.org/10.1081/TMA-120020259
dc.identifier.urihttps://hdl.handle.net/20.500.14551/20489
dc.identifier.volume21en_US
dc.identifier.wosWOS:000183378600004en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherMarcel Dekker Incen_US
dc.relation.ispartofJournal Of Trace And Microprobe Techniquesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDiethylenetriamineen_US
dc.subjectPreconcentrationen_US
dc.subjectCoen_US
dc.subjectMnen_US
dc.subjectNien_US
dc.subjectAtomic Absorption Spectrometryen_US
dc.subjectAtomic-Absorption-Spectrometryen_US
dc.subjectSolid-Phase Extractionen_US
dc.subjectOnline Preconcentrationen_US
dc.subjectFlow-Injectionen_US
dc.subjectSeparationen_US
dc.subjectCopperen_US
dc.subjectCadmiumen_US
dc.subjectResinen_US
dc.subjectZincen_US
dc.subjectLeaden_US
dc.titleDetermination of some trace heavy metals in some water samples by FAAS after their preconcentration using DETAen_US