Determination of some trace heavy metals in some water samples by FAAS after their preconcentration using DETA
dc.authorid | senkal, bahire filiz/0000-0002-1616-6828 | |
dc.authorid | Bakircioglu Kurtulus, Yasemin/0000-0003-3013-5793 | |
dc.authorid | Akman, Suleyman/0000-0002-8625-783X | |
dc.authorwosid | senkal, bahire filiz/N-1850-2014 | |
dc.authorwosid | Bakircioglu Kurtulus, Yasemin/Q-2570-2017 | |
dc.authorwosid | Akman, Suleyman/C-1418-2014 | |
dc.contributor.author | Bakircioglu, Y | |
dc.contributor.author | Akman, S | |
dc.contributor.author | Biçak, N | |
dc.contributor.author | Senkal, F | |
dc.date.accessioned | 2024-06-12T10:59:37Z | |
dc.date.available | 2024-06-12T10:59:37Z | |
dc.date.issued | 2003 | |
dc.department | Trakya Üniversitesi | en_US |
dc.description.abstract | Diethylenetriamine, DETA polymer was used as a preconcentration of cobalt, iron and nickel prior to their determination by flame atomic. ab-sorption spectrometry (FAAS). Both batch-and column methods were used for the separation and concentration of above metals. These metals were quantitatively retained on the proposed adsorbent at pH 21 then were quantitatively eluted with 2 M hydrochloric acid or nitric acid. The recoveries of metal ions were greater than 98%. Detection limits (3 delta) were 1.5 g/L for Co, 2 . I g/L for Fe and 1.9 g/L for Ni. The relative standard deviations for the determinations were found to be 1.0-8.8%. The effect of Na on the preconcentration of trace metals has also been investigated. The method was applied to tap, ground and lake water samples. | en_US |
dc.identifier.doi | 10.1081/TMA-120020259 | |
dc.identifier.endpage | 248 | en_US |
dc.identifier.issn | 0733-4680 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopus | 2-s2.0-0038205880 | en_US |
dc.identifier.scopusquality | N/A | en_US |
dc.identifier.startpage | 239 | en_US |
dc.identifier.uri | https://doi.org/10.1081/TMA-120020259 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14551/20489 | |
dc.identifier.volume | 21 | en_US |
dc.identifier.wos | WOS:000183378600004 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Marcel Dekker Inc | en_US |
dc.relation.ispartof | Journal Of Trace And Microprobe Techniques | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Diethylenetriamine | en_US |
dc.subject | Preconcentration | en_US |
dc.subject | Co | en_US |
dc.subject | Mn | en_US |
dc.subject | Ni | en_US |
dc.subject | Atomic Absorption Spectrometry | en_US |
dc.subject | Atomic-Absorption-Spectrometry | en_US |
dc.subject | Solid-Phase Extraction | en_US |
dc.subject | Online Preconcentration | en_US |
dc.subject | Flow-Injection | en_US |
dc.subject | Separation | en_US |
dc.subject | Copper | en_US |
dc.subject | Cadmium | en_US |
dc.subject | Resin | en_US |
dc.subject | Zinc | en_US |
dc.subject | Lead | en_US |
dc.title | Determination of some trace heavy metals in some water samples by FAAS after their preconcentration using DETA | en_US |
dc.type | Article | en_US |