Determination of some trace heavy metals in some water samples by FAAS after their preconcentration using DETA
Küçük Resim Yok
Tarih
2003
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Marcel Dekker Inc
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Diethylenetriamine, DETA polymer was used as a preconcentration of cobalt, iron and nickel prior to their determination by flame atomic. ab-sorption spectrometry (FAAS). Both batch-and column methods were used for the separation and concentration of above metals. These metals were quantitatively retained on the proposed adsorbent at pH 21 then were quantitatively eluted with 2 M hydrochloric acid or nitric acid. The recoveries of metal ions were greater than 98%. Detection limits (3 delta) were 1.5 g/L for Co, 2 . I g/L for Fe and 1.9 g/L for Ni. The relative standard deviations for the determinations were found to be 1.0-8.8%. The effect of Na on the preconcentration of trace metals has also been investigated. The method was applied to tap, ground and lake water samples.
Açıklama
Anahtar Kelimeler
Diethylenetriamine, Preconcentration, Co, Mn, Ni, Atomic Absorption Spectrometry, Atomic-Absorption-Spectrometry, Solid-Phase Extraction, Online Preconcentration, Flow-Injection, Separation, Copper, Cadmium, Resin, Zinc, Lead
Kaynak
Journal Of Trace And Microprobe Techniques
WoS Q Değeri
Q2
Scopus Q Değeri
N/A
Cilt
21
Sayı
2