Effect of Dual Mesh Wrap on The Stability of Colonic Anastomosis

dc.authorwosidOguz, Serhat/HKE-2793-2023
dc.contributor.authorAlbayrak, Dogan
dc.contributor.authorTurkes, Bayram
dc.contributor.authorCan, Nuray
dc.contributor.authorCakcak, Ibrahim Ethem
dc.contributor.authorKahya, Eyup
dc.contributor.authorOguz, Serhat
dc.contributor.authorHoscoskun, Zeki
dc.date.accessioned2024-06-12T10:58:08Z
dc.date.available2024-06-12T10:58:08Z
dc.date.issued2021
dc.departmentTrakya Üniversitesien_US
dc.description.abstractBACKGROUND/AIMS Colon anastomotic leakage is the cause of significant morbidity and mortality in surgery. Therefore, we aimed to demonstrate experimentally the effect of the conventional method of wrapping them through colo-colonic anastomosis performed by dual patch on anastomotic healing and security. MATERIAL and METHODS The study was conducted at the Experimental Animal Research Unit of the Medical Faculty of Trakya University, Edirne, Turkey. A total of 20 Wistar Albino adult rats were used. The rats were divided into 2 groups: 10 rats in the control group and 10 rats in the dual patch group. All rats underwent partial segmental colon resection, and colo-colonic anastomosis was performed in a single layer with 5/0 polypropylene. For rats in the dual patch group, the anastomosis was wrapped up with a 1-cm-wide dual patch. In the control group, there was no operation on the anastomosis. At 7 days after the procedure, the degree of peritoneal adhesion model previously prepared according to Evans devices laparotomy was used to observe all the rats and colon burst pressure. Both histopathological examination and the examination of the perianastomotic area were performed. RESULTS In the rats that were treated with dual mesh, there was a statistically significant increase in anastomotic line burst pressure (P<.05), a statistically significant increase in collagen amount (P<.05), and a statistically significant decrease in abdominal adhesions (P<.05). CONCLUSION As a result, the colo-colonic anastomosis of winding dual patch, without causing intra-abdominal adhesions, improves security by increasing the anastomosis bursting pressure.en_US
dc.identifier.doi10.5152/cjms.2021.1049
dc.identifier.endpage17en_US
dc.identifier.issn2149-7893
dc.identifier.issn2536-507X
dc.identifier.issue1en_US
dc.identifier.startpage13en_US
dc.identifier.trdizinid472267en_US
dc.identifier.urihttps://doi.org/10.5152/cjms.2021.1049
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/472267
dc.identifier.urihttps://hdl.handle.net/20.500.14551/19954
dc.identifier.volume6en_US
dc.identifier.wosWOS:000646579800003en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isoenen_US
dc.publisherAvesen_US
dc.relation.ispartofCyprus Journal Of Medical Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectColorectal Surgeryen_US
dc.subjectMeshen_US
dc.subjectAnastomotic Leakageen_US
dc.titleEffect of Dual Mesh Wrap on The Stability of Colonic Anastomosisen_US
dc.typeArticleen_US