Evaluation of the Internal and Marginal Discrepancies of Co-Cr Metal Copings Prepared via CAD/CAM and Conventional Casting
dc.authorid | dayan, süleyman çağatay/0000-0003-3081-9618 | |
dc.authorid | Kurt, Aysegul/0000-0003-2775-3179 | |
dc.authorid | GENÇEL, Burç İhsan/0000-0003-4982-3705 | |
dc.authorid | Kurt, Aysegul/0000-0003-2775-3179 | |
dc.authorwosid | dayan, süleyman çağatay/AAH-9997-2019 | |
dc.authorwosid | Kurt, Aysegul/Y-9162-2019 | |
dc.authorwosid | dayan, süleyman çağatay/CAG-6167-2022 | |
dc.authorwosid | GENÇEL, Burç İhsan/AAD-7932-2021 | |
dc.authorwosid | Kurt, Aysegul/HJH-9446-2023 | |
dc.contributor.author | Dayan, Suleyman Cagatay | |
dc.contributor.author | Kiseri, Burim | |
dc.contributor.author | Gencel, Burc | |
dc.contributor.author | Kurt, Aysegul | |
dc.date.accessioned | 2024-06-12T10:58:20Z | |
dc.date.available | 2024-06-12T10:58:20Z | |
dc.date.issued | 2019 | |
dc.department | Trakya Üniversitesi | en_US |
dc.description.abstract | The aim of this study was to assess the internal and marginal discrepancies of chromium-cobalt (Co/Cr) copings fabricated using different techniques. A typodont molar tooth was prepared and replicated in die stone and scanned. Forty Co-Cr alloy copings were produced using four different production techniques: conventional casting (C-group), direct metal laser sintering (DMLS-group), micro-stereolithography/casting combination (mu SLA-group), and computer-aided milling (M-group) (n = 10). The internal and marginal discrepancies at various reference points were determined via digital microscopy. Analysis of variance (ANOVA) and Tukey's multiple comparisons tests were used for statistical analysis (p=0.05). The marginal and cervical discrepancies of the C-group were similar to those of the M-group (p>0.05) and better than those of the mu SLA-group (p<0.05). The marginal and internal discrepancies of all groups were within clinically acceptable limits, but further improvements in the mu SLA and DMLS techniques may be required prior to clinical implementation. | en_US |
dc.identifier.doi | 10.1922/EJPRD_01865Dayan06 | |
dc.identifier.endpage | 31 | en_US |
dc.identifier.issn | 0965-7452 | |
dc.identifier.issn | 2396-8893 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | 30762994 | en_US |
dc.identifier.scopus | 2-s2.0-85062098593 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 26 | en_US |
dc.identifier.uri | https://doi.org/10.1922/EJPRD_01865Dayan06 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14551/20021 | |
dc.identifier.volume | 27 | en_US |
dc.identifier.wos | WOS:000459372800004 | en_US |
dc.identifier.wosquality | N/A | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | Dennis Barber Ltd | en_US |
dc.relation.ispartof | European Journal Of Prosthodontics And Restorative Dentistry | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Computer-Aided Design | en_US |
dc.subject | Alloys | en_US |
dc.subject | Computer-Aided Manufacture | en_US |
dc.subject | Marginal Discrepancy | en_US |
dc.subject | Internal Discrepancy | en_US |
dc.subject | Fit | en_US |
dc.subject | Crowns | en_US |
dc.subject | Adaptation | en_US |
dc.subject | Accuracy | en_US |
dc.subject | Future | en_US |
dc.subject | Gaps | en_US |
dc.title | Evaluation of the Internal and Marginal Discrepancies of Co-Cr Metal Copings Prepared via CAD/CAM and Conventional Casting | en_US |
dc.type | Article | en_US |