Effect of dentin desensitizers and Nd:YAG laser pre-treatment on microshear bond strength of adhesive resin cement to dentin

Küçük Resim Yok

Tarih

2019

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Cumhuriyet University Faculty of Dentistry

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Objectives: The aim of this study was to evaluate how microshear bond strength of different adhesive resin cements are affected by dentin desensitizers application and preparation depth. Materials and Methods: One hundred and forty-four maxillary incisors were randomly divided into two groups according to dentin preparation depth (0.8 and 1 mm) and each group subdivided into four dentin desensitizers, Nd:YAG (Neodymium-doped Yttrium aluminum Garnet) laser and control groups. The dentin desensitizers used were Gluma [Glutaraldehyde/ Hydroxyethyl methacrylate (HEMA)], BisBlock (Oxalate) Vivasens-Potassium Fluoride (KF) and Admira Protect (Ormocer/HEMA), respectively. Three dual cure resin based luting cement (RelyX ARC; Variolink II and Maxcem Elite) were used to create a 0.7 mm diameter and 1 mm height cylindirical shape buid-up in tygon tubes (n=10). Micro-shear bond strength (?SBS) test was performed at a crosshead of speed of 0.5 mm/min using a Universal testing device. Then tooth surface was investigated by steromicroscope and scanning electron microscopy (SEM). Data were analyzed using Kruskal-Wallis, Mann-Whitney U and Chi-Square (X2) tests. (p = 0.05) Results: There was no statistically difference between the groups at 0.8 mm preparation depth. At 1 mm preparation dept RelyX ARC + Gluma groups' mean bond strength value (23.96 ± 6.66 MPa) was found statistically lower according to the other groups (p < 0.05). RelyX ARC + Laser groups' mean bond strength value (37.33 ± 7.39 MPa) was found statistically higher according to the other groups (p < 0.05). Conclusions: The use of desensitizing agents affected the bond strength of the resin cements to superficial dentin. Gluma desensitizer affected negatively ?SBS of RelyX ARC resin cement at 1 mm depth. Application of Nd:YAG laser to superficial dentin showed positive effects to the dentin surface and bond strength. Other desensitizing agents showed no significant effects on the resin bond strength (p > 0.05). © 2019 Cumhuriyet Dental Journal.

Açıklama

Anahtar Kelimeler

Dentin Desensitizing Agents; Dentin Sensitivity; Resin Cements; Shear Strength

Kaynak

Cumhuriyet Dental Journal

WoS Q Değeri

Scopus Q Değeri

Q4

Cilt

22

Sayı

2

Künye