Teknezyum 99m dimerkaptosüksinik asid spect görüntülerinde uygulanan filtrelenmiş geri projeksiyon ve iterativ rekonstrüksiyon yöntemlerinin görüntü kalitesi üzerine etkilerinin belirlenmesi Determination of filtered back projection and iterative reconstruction algoritms effect on image quality in technetium-99m dimercaptosuccinic acid renal spect

dc.contributor.advisorDurmuş Altun, Gülay
dc.contributor.authorBedel, Deniz
dc.date.accessioned2014-04-03T15:49:48Z
dc.date.available2014-04-03T15:49:48Z
dc.date.issued2006
dc.departmentFakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Nükleer Tıp Ana Bilim Dalıen_US
dc.description.abstractÖZET Dimerkaptosüksinik asid böbrek sintigrafisi, çocuk ve yetişkinlerde böbrek parankiminin değerlendirilmesinde yaygın olarak kabul edilen referans yöntemdir. Planar teknikte alınan iki boyutlu görüntülerle böbrek korteksi değerlendirilir. Son çalışmalarda, böbreklerdeki lokalize patolojilerin belirlenmesinde SPECT çalışmasının duyarlılığının daha yüksek olduğu belirtilmektedir. Bu çalışmada, 360° ve posteriyor 180° dimerkaptosüksinik asid SPECT görüntüleri elde edilerek, filtrelenmiş geri projeksiyon ve iterativ yeniden yapılandırma yöntemleriyle işlemlenmiştir. Her iki görüntüleme ve yeniden yapılandırma teknikleri birbiriyle karşılaştırılarak görüntü kalitesi ve lezyon saptanması üzerindeki etkilerinin belirlenmesi amaçlanmıştır. Çalışma grubuna bir yıllık süreçte Tc-99m dimerkaptosüksinik asid ile planar ve SPECT böbrek görüntülemesi yapılan 37 hasta (3 erkek, 34 kadın, ortalama yaş: 20±15 yıl) dahil edildi. Hastalar yaşlarına göre çocuk (grup A, n=23, ortalama yaş: 9±2 yıl) ve erişkin (grup B, n=14, ortalama yaş: 38±9 yıl) hasta olmak üzere iki alt gruba ayrıldı. Hastalar ayrıca Tc-99m dimerkaptosüksinik asid sintigrafisi sonucuna göre normal (n=19) ve patolojik (n=18) olmak üzere iki gruba ayrıldı ve normal grupta yer alanların görüntüleri, farklı işlemleme tekniklerinin görüntü kalitesinin karşılaştırılmasında kullanıldı. SPECT180İR tekniği hem görsel değerlendirmede hem de lezyon saptanmasında planar teknikle en uyumlu sonuçları vermiştir (κ=0.57, p=0.001, r=0.70, p=0.0001). Görüntü kontrastı 180° SPECT görüntülerinde, 360° SPECT görüntülerinden daha yüksek bulunmuştur. SPECT360FBP en fazla yalancı pozitif sonuç veren yöntemdir. Hem SPECT180İR hem de SPECT180FBP ile planar görüntülemeden daha fazla sayıda defekt saptanmıştır. SPECT180İR'nin defekt saptama gücü SPECT180FBP ile benzerdi, ancak görüntü kalitesi göreceli olarak daha iyiydi. Tc-99m DMSA, böbrek, sintigrafi, SPECT, yeniden Anahtar Kelimeler: yapılandırmaen_US
dc.description.abstractDETERMINATION OF FILTERED BACK PROJECTION AND ITERATIVE RECONSTRUCTION ALGORITMS EFFECT ON IMAGE QUALITY IN TECHNETIUM-99m DIMERCAPTOSUCCINIC ACID RENAL SPECT SUMMARY Dimercaptosuccinic acid renal scintigraphy is the most commonly accepted reliable imaging technique for evaluation of renal paranchima in both children and adults. The traditional planar technique provides adequate two dimensional imaging of the renal cortex. Recent reports suggested that compared to planar imaging, SPECT has higher sensitivity for the detection of focal abnormalities in the kidneys. In this study, posterior 180° and 360° dimercaptosuccinic acid SPECT images were obtained. SPECT images were reconstructed with filtred back-projection and iterative algoritms. The aim of this study was determine the effect of filtred back projection and iterative reconstruction algoritms on image quality and lesion detection in both acquisitions. Thirty seven consequtive patients (3 men, 34 women, mean age: 20±15 years) examined with Tc-99m dimercaptosuccinic acid imaging in both planar and SPECT acquisitions during the one year were included in this study. Study group were divided into two subgroup according to the age of patients: Grup A as child patients (younger than 18 years-old, n=23, mean age: 9±2 years) and Grup B as adult patients (older or equal 18 years- old, n=14, mean ages: 38±9 years). Patients were divided into other two subgrups based on the results of planar dimercaptosuccinic acid images, normal (n=19) and pathologic (n=18).The images of the normal planar dimercaptosuccinic acid group were used for the evaluation of the image qualities of our reconstruction methods. SPECT180IR tecnique showed the most similarity with planar imaging on both visual evaluation and lesion area detection (κ=0.57, p=0.001, r=0.70, p=0.0001 respectively). The posterior 180° DMSA SPECT has higher lesion contrast in comparison with 360° acquisition. SPECT360FBP failed to determine many of the cortical defects, and its had the most frequent false positive results. Both SPECT180İR and SPECT180FBP significantly detected more of the renal defects than planar imaging. The sensibilty of posterior SPECT180İR in the detection of renal defects was equal to SPECT180FBP, but its visual image quality was better. Key words: Tc-99m DMSA, kidney, scintigraphy, SPECT, reconstruction.en_US
dc.identifier.urihttps://hdl.handle.net/20.500.14551/235
dc.identifier.yoktezid193895en_US
dc.language.isotren_US
dc.relation.publicationcategoryTezen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectRadyoloji ve Nükleer Tıpen_US
dc.subjectRadiology and Nuclear Medicineen_US
dc.titleTeknezyum 99m dimerkaptosüksinik asid spect görüntülerinde uygulanan filtrelenmiş geri projeksiyon ve iterativ rekonstrüksiyon yöntemlerinin görüntü kalitesi üzerine etkilerinin belirlenmesi Determination of filtered back projection and iterative reconstruction algoritms effect on image quality in technetium-99m dimercaptosuccinic acid renal specten_US
dc.typeSpecialist Thesisen_US
dc.type.descriptionNo: 0141222en_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
0057635.pdf
Boyut:
1004.15 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.7 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: