The Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Study

dc.authoridGECKILI, ONUR/0000-0002-7852-3915
dc.authoridBilmenoglu, Caglar/0000-0002-2580-9899
dc.authoridCilingir, Altug/0000-0002-0694-5772
dc.authoridBilhan, Hakan/0000-0003-1787-3003
dc.authorwosidGECKILI, ONUR/AAD-4973-2020
dc.authorwosidBURAL, HAYRUNNİSA CANAN/AAE-1151-2020
dc.authorwosidBilmenoglu, Caglar/HGE-5706-2022
dc.authorwosidSakar, Olcay/AAD-4997-2020
dc.authorwosidCilingir, Altug/N-2262-2018
dc.contributor.authorBilhan, Hakan
dc.contributor.authorCilingir, Altug
dc.contributor.authorBural, Canan
dc.contributor.authorBilmenoglu, Caglar
dc.contributor.authorSakar, Olcay
dc.contributor.authorGeckili, Onur
dc.date.accessioned2024-06-12T11:07:09Z
dc.date.available2024-06-12T11:07:09Z
dc.date.issued2015
dc.departmentTrakya Üniversitesien_US
dc.description.abstractPeriotest (Medizintechnik Gulden, Modautal, Germany) is a widely accepted implant stability measurement method, although the reliability is not well known. The aim of this in vitro study was to investigate the reliability of the Periotest in implant stability measurements. Thirty implants were placed in 3 cow ribs. The stability of each implant was measured by insertion torque, resonance frequency analyses, and Periotest and then compared. The Periotest values (PTVs) were measured by 4 different examiners. The measurements were repeated twice in both the buccal and mesial directions, for each implant at 2-hour intervals and the intra-and interobserver reliability of Periotest was measured. Results showed that the intraobserver reliability of the Periotest was excellent for the buccal PTVs but fair to poor for the mesial PTVs. The interobserver reliability of the Periotest was excellent for the buccal PTVs but poor for the mesial PTVs. No significance was found between the PTVs and IT values (P =.803) and PTVs and ISQ values, whereas a 47.1% significant correlation was detected between the IT values and ISQ values (P =.009). The present study indicates that only Periotest measurements from buccal result in excellent intra-and interobserver reliability for the quantification of the implant stability.en_US
dc.identifier.doi10.1563/AAID-JOI-D-13-00303
dc.identifier.endpageE95en_US
dc.identifier.issn0160-6972
dc.identifier.issn1548-1336
dc.identifier.issue4en_US
dc.identifier.pmid24593232en_US
dc.identifier.scopus2-s2.0-84939487548en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpageE90en_US
dc.identifier.urihttps://doi.org/10.1563/AAID-JOI-D-13-00303
dc.identifier.urihttps://hdl.handle.net/20.500.14551/21925
dc.identifier.volume41en_US
dc.identifier.wosWOS:000360159000001en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherAllen Press Incen_US
dc.relation.ispartofJournal Of Oral Implantologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIn Vitro Modelen_US
dc.subjectDental Implanten_US
dc.subjectStatisticsen_US
dc.subjectPeriotesten_US
dc.subjectResonance Frequency Analysisen_US
dc.subjectOsstellen_US
dc.subjectInsertion Torqueen_US
dc.subjectImplant Stabilityen_US
dc.subjectResonance Frequency-Analysisen_US
dc.subjectDamping Capacity Assessmenten_US
dc.subjectInsertion Torqueen_US
dc.subjectDental Implantsen_US
dc.subjectClinical-Trialen_US
dc.subjectBone Lossen_US
dc.subjectInterfaceen_US
dc.subjectMandiblesen_US
dc.subjectImmediateen_US
dc.subjectValidityen_US
dc.titleThe Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Studyen_US
dc.typeArticleen_US

Dosyalar