Macular function of successfully repaired macula-off retinal detachments
dc.authorid | Esgin, Haluk/0000-0002-6611-6132 | |
dc.authorwosid | Esgin, Haluk/H-6460-2013 | |
dc.contributor.author | Ozgur, Soykan | |
dc.contributor.author | Esgin, Haluk | |
dc.date.accessioned | 2024-06-12T10:58:25Z | |
dc.date.available | 2024-06-12T10:58:25Z | |
dc.date.issued | 2007 | |
dc.department | Trakya Üniversitesi | en_US |
dc.description.abstract | Purpose: To assess the macular function of successfully repaired macula-off retinal detachments in the long term and to evaluate the relationship between duration of macular detachment and functional recovery. Methods: Of 214 consecutive patients, 29 who were operated on because of unilateral retinal detachment with at least 6 months of follow-up and whose best-corrected visual acuity was better than 0.05 Snellen chart value in both eyes were examined. Operated eyes were included in group I, and the fellow eyes were included in group II. Macular functions were evaluated in terms of visual acuity, contrast sensitivity, color vision, visual field, and visual evoked potentials after reattachment. Results: All macular functions except P100 amplitudes in the operated eyes were significantly less than those in the fellow eyes (P = 0.28) following reattachment after nearly 5 years. It was found that the longer the duration of macular detachment (except detachment duration of <= 7 days), the smaller the increase in visual acuity, contrast sensitivity, and color vision defect scores (P = 0.000, P = 0.034, and P = 0.0003, respectively). Conclusions: Macular functions except P100 amplitude cannot be recovered completely 5 years after retinal reattachment. There was no relation between the duration of macular detachment and the mean deviation in visual field and the P100 latency and P100 amplitude difference between both eyes. | en_US |
dc.identifier.endpage | 364 | en_US |
dc.identifier.issn | 0275-004X | |
dc.identifier.issue | 3 | en_US |
dc.identifier.pmid | 17460592 | en_US |
dc.identifier.scopus | 2-s2.0-33947190017 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 358 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.14551/20063 | |
dc.identifier.volume | 27 | en_US |
dc.identifier.wos | WOS:000246985100012 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | Lippincott Williams & Wilkins | en_US |
dc.relation.ispartof | Retina-The Journal Of Retinal And Vitreous Diseases | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Contrast Sensitivity | en_US |
dc.subject | Color Vision | en_US |
dc.subject | Macular Reattachment | en_US |
dc.subject | Retinal Detachment | en_US |
dc.subject | Retinal Detachment Surgery | en_US |
dc.subject | Visual Acuity | en_US |
dc.subject | Visual Field | en_US |
dc.subject | Visual Evoked Potential | en_US |
dc.subject | Munsell 100-Hue Test | en_US |
dc.subject | Contrast Sensitivity | en_US |
dc.subject | Visual Function | en_US |
dc.subject | Central Vision | en_US |
dc.subject | Owl Monkey | en_US |
dc.subject | Surgery | en_US |
dc.subject | Acuity | en_US |
dc.subject | Recovery | en_US |
dc.title | Macular function of successfully repaired macula-off retinal detachments | en_US |
dc.type | Article | en_US |