Lyapunov Function-Based Control of Active Power Filters to Reduce the Adverse Effects of Harmonics on Induction Motors

Küçük Resim Yok

Tarih

2013

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

IEEE

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this study, a pulse width modulator controller inverter type active power filter is used for reducing the adverse effects of harmonics. Induction motor control system used in this study comprises a proportional-integral controller, a direct torque control algorithm, and an inverter module. Nonlinear controller algorithm proposed in this study enables setting different parameters in the controller system. Our experimental results show that more planar electromagnetic torque can be obtained by using the proposed controller-based filter than a classical controlled-based filter.

Açıklama

3rd International Conference on Electric Power and Energy Conversion Systems (EPECS) -- OCT 02-04, 2013 -- Yildiz Tech Univ, Davutpasa Campus, Istanbul, TURKEY

Anahtar Kelimeler

Active Power Filters, Harmonics, Lyapunov Function, Drives

Kaynak

2013 3rd International Conference On Electric Power And Energy Conversion Systems (Epecs)

WoS Q Değeri

N/A

Scopus Q Değeri

Cilt

Sayı

Künye