Numerical investigation of general and local thermal comfort of an office equipped with radiant panels

dc.authoridYilmaz, Berrin/0000-0001-9142-0817
dc.authoridAydin, Kadir/0000-0002-6387-1589
dc.contributor.authorKaracavus, Berrin
dc.contributor.authorAydin, Kadir
dc.date.accessioned2024-06-12T11:02:33Z
dc.date.available2024-06-12T11:02:33Z
dc.date.issued2019
dc.departmentTrakya Üniversitesien_US
dc.description.abstractThermal comfort of an office environment is one of the most important factors affecting the performance of employees. One of the systems used in heating and cooling of offices is the radiant system which can create a thermal environment at acceptable levels. In this study, general and local thermal comfort of an office with a dimension of 3 m x 6 m x 3.5 m, where two manikins are positioned next to each other, are numerically studied with the help of computational fluid dynamics. Two different models were created for analyses. In the first model, the panel was placed below a window whereas in the second it was positioned on the ceiling. For each model, analyses were carried out at different temperatures and with different panel heat fluxes. The compliance of the office's general and local comfort levels with ISO 7730 was evaluated taking into account results of analyses. The calculation revealed that general and local comfort levels for these models were not in compliance with ISO 7730 when the outside temperature was -10 degrees C. However, when the outside temperature was 3.3 degrees C and 10 degrees C, the general and local thermal values of both models were within acceptable limits.en_US
dc.identifier.doi10.1177/1420326X18799834
dc.identifier.endpage824en_US
dc.identifier.issn1420-326X
dc.identifier.issn1423-0070
dc.identifier.issue6en_US
dc.identifier.scopus2-s2.0-85060110816en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage806en_US
dc.identifier.urihttps://doi.org/10.1177/1420326X18799834
dc.identifier.urihttps://hdl.handle.net/20.500.14551/21328
dc.identifier.volume28en_US
dc.identifier.wosWOS:000472574200007en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherSage Publications Ltden_US
dc.relation.ispartofIndoor And Built Environmenten_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGeneral Thermal Comforten_US
dc.subjectLocal Thermal Comforten_US
dc.subjectRadiant Heatingen_US
dc.subjectRadiant Panelen_US
dc.subjectISO 7730en_US
dc.subjectCFDen_US
dc.subjectAir-Flowen_US
dc.subjectSystemen_US
dc.subjectRoomen_US
dc.titleNumerical investigation of general and local thermal comfort of an office equipped with radiant panelsen_US
dc.typeArticleen_US